Brief Introduction
The operating regime of clockwise and anticlockwise rotation motor refers to the way the motor operates under specific conditions. According to the standards of the International Electrotechnical Commission (IEC), the operating regimes of clockwise and anticlockwise rotation motor is mainly categorized as follows:
S1 Duty refers to the continuous operation of the motor under rated load without overheating during operation. This kind of working regime is suitable for the occasions which need to run steadily for a long time, such as water pumps, fans, and so on.
S2 Duty means that the motor runs under the rated load for a period of time and then stops, which is suitable for occasions requiring high loads for a short period of time, such as cranes.
S3 Duty refers to the motor running under rated load for a period of time and then stopping for a period of time and then restarting, applicable to the occasions of cyclical work, such as conveyor belts.
S4 Duty means that the motor starts and stops repeatedly under the rated load, which is applicable to the occasions requiring frequent starting, such as elevators.
S1 Duty clockwise and anticlockwise rotation motor offers a variety of advantages that make them popular in industrial applications.
Clockwise and anticlockwise rotation motor is able to maintain high efficiency and reduce energy loss when operating at rated loads. This not only helps to reduce operating costs, but also reduces the impact on the environment.
Since the S1 Duty clockwise and anticlockwise rotation motor is designed for continuous operation, it maintains stable performance over long periods of time, reducing failure rates. This is especially important for equipment that requires long periods of uninterrupted operation.
Clockwise and anticlockwise rotation motor is relatively simple to construct and easy to maintain and service. Regular inspection and lubrication of the bearings and cleaning of the casing are all that is required to extend the life of the motor.
Clockwise and anticlockwise rotation motor is suitable for a wide range of operating environments, including high temperatures, high humidity, dust and other harsh conditions. This allows them to perform well in a wide range of industrial applications.
The clockwise and anticlockwise rotation motor produces low noise during operation, which meets modern industrial requirements for noise control and is suitable for use in noise-sensitive environments.
Main Technical Parameters
Frame
H630mm
Power Scope
710kW~1120kW
Voltage
6kV
Frequency
50Hz, 60Hz
Number of Poles
12P
Speed
495rpm
Cooling Mechod
IC611
Protection Grade
IP55
Insulation Class
F(155℃)
Duty
S1
Mounting Type
IM B3
Outline Dimensions
Motor Parameters