Welcome to Xi'an Simo Motor Co., Ltd.

Category:High voltage AC motors
Release Date:2025-09-12
Model:
Views:1
Tel: +86 15523831294
Related Products
Brief Introduction
3 phase induction motor slip ring, also known as wound rotor motors, are the core of many high-power transmission applications. They are more commonly used in the raw material industry such as mining ore, mineral raw material industry or adhesive industry such as cement, limestone, gypsum of various crushers, rollers, grinding machines in the processing process, is also used in large fans, pumps and conveyors.
The stator structure of the squirrel cage motor and the slip ring motor is the same, the main difference of the slip ring induction motor is the rotor structure and operation mode, when the slip ring motor is used in the cascade system, it may encounter some changes in the stator, because the power supply from the motor comes from the power control of the rotor of the other slip ring motor, in which the external resistance is installed on its rotor.
What is a slip ring? A slip ring motor usually has a phase-wound rotor, this type of rotor has a three-phase double-layer distributed winding consisting of a coil used in an alternator, and the rotor core consists of a steel stack with slots to accommodate the formed 3-phase single-phase windings, which are electrically separated by 120 degrees.
Even if the stator is wound in two phases, and the rotor is wound in as many stators as there are in the stator, and is always three phases, these three windings are drawn out at the other end of the interior and connected to three insulating slip rings mounted on the rotor shaft itself. The three terminals touch the three slip rings with the help of a carbon brush, which is secured to the rings with the help of a spring assembly.
The three carbon brushes are further externally connected to a rheostat with a three-phase starter connection. Slip rings and external rheostat can increase the external resistance of the rotor circuit, giving it a higher resistance at startup, thus increasing the starting torque.
Main Technical Parameters
Frame
H800mm
Power Scope
2240kW~3150kW
Voltage
6kV
Frequency
50Hz, 60Hz
Number of Poles
10P
Speed
595rpm
Cooling Mechod
IC01/IC81W
Protection Grade
IP54
Insulation Class
F(155℃)
Duty
S1
Mounting Type
IM B3
Outline Dimensions
Motor Parameters
2025-10-28
sharon@chinasimo.com
3771550493